| Only use Corona endorsed fluids in
accordance with stipulated safety precautions.
* Unscrew the canister top. * Add 15 US oz. (450 ml) of smoke fluid (2 full measuring
cups). * Replace canister top – tighten sufficiently to
ensure seal is noticeably
engaged. *
Pressurize to 100 psi keeping
the canister upright and applying clean air (or
using the companion pump), CO2, Nitrogen or Helium at the Schrader valve on the side of the canister top (do not use any
other pressurizing
gas). * DO NOT OVER-FILL
OR OVER-PRESSURIZE. * Between operations,
remove the canister from the smoke generator and
depressurize by activating the needle valve or carefully removing the top – keeping the canister
upright.
NOTE: a pressurized canister is subject
to public transport regulations for DANGEROUS GOODS
For exclusive use in Corona Smoke
generators.
|