MATERIAL SAFETY DATA SHEET

 

PRODUCT IDENTIFICATION AND USE
 
Product:                    Corona Smoke Fluid 300C
Product code:             300C-2
Product use:               Generators producing a thermal aerosol (Evolution Series, Colt3, SpiritB. 300C)
Manufacturer:             Corona Integrated Technologies Inc., 6215 Overstone Drive,
                                West Vancouver, B.C., Canada. V7W 1X7 Telephone: 1-888-878-9433
                                Emergency telephone number: 1-888-878-9433
 
No significant immediate hazards for emergency response are known.

HAZARDOUS INGREDIENTS
 
Ingredients:                 Contains dipropylene glycol (CAS# 110-98-5) and de-ionized water
                                 (In some instances these constituents are pressurized by oxygen free nitrogen)
 
PHYSICAL DATA
 
Physical State:               Colorless, slightly viscous liquid
Odor/Appearance:           Practically odorless
Vapor pressure:               < 0,01 mmHg @ 20oC
Vapor density:               4.63   
Evaporation rate:           Not available
Boiling Point:                 451oF, 233oC
Specific gravity:            1.0252 @ 20oC
 
FIRE AND EXPLOSION DATA
 
Flash point:                       255oF, 124oC
Method used:                     PMCC
Upper flammable limit:          12.6%
Lower flammable limit:          2.2%
Auto-ignition temperature:    435oF, 224oC
 
REACTIVITY DATA
 
Chemical stability:                            Normally stable
Incompatibility with other materials:    Oxidizing material
Hazardous decomposition products:     When available oxygen is limited (as in a fire), carbon monoxide
                                                    and other hazardous compounds may be formed.

TOXICOLOGICAL PROPERTIES
 
Eye:                         May cause slight transient eye irritation.         
Skin:                        Single prolonged exposure is not likely to result in absorption 
                               through the skin in harmful amounts.
LD 50 rabbits             > 5g/kg.
Oral:                         Single dosage oral toxicity is low and implies no hazard.
LD 50 Rats                14.8g/kg.
Inhalation:                Single prolonged exposure is not likely to cause adverse effects.
                              Mists are not likely to be hazardous.
Carcinogenicity:         None (under HTP, IARC and OSHA).
Mutagenicity:            In vitro mutagenicity studies were negative.
PREVENTATIVE MEASURES
 
Eye/face protection:          Use safety glasses.
Skin protection:                No precautions other than clean body-covering clothing should be needed.
Respiratory protection:       Atmospheric levels should be maintained below the exposure guideline.
                                      For most conditions, no respiratory protection should be needed.
Disposal:                          All disposal methods must be in compliance with all Federal, State/Provincial
                                      and local laws and regulations. Regulations may vary in different locations.
Storage:                          Storage temperature not to exceed 50oC.
Fire extinguishing media:     Water fog or fine spray, carbon dioxide, dry chemical and foam.
 
FIRST AID
 
Eyes:              Flush eyes with plenty of water.
Skin:               Wash off in flowing water or shower.
Ingestion:        If swallowed, seek medical attention.
                     (Do not induce vomiting unless directed to do so by medical personnel).
Inhalation:       Remove to fresh air if effects occur. Consult a physician.
 
 
TRANSPORT INFORMATION
 
Canadian Transportation of Dangerous Goods:       Not specifically listed in the dangerous goods regulations
U.S. Department of Transport:                            Not specifically listed in the hazardous materials shipping regulations
 
Corona Integrated Technologies Inc. has no control over the management practices or manufacturing processes of parties handling or using this material. The information presented here pertains only to the product as shipped in its intended condition as described herein.
 
Effective Date: 01/15/2003                   Updated on    

The information herein is given in good faith, but no warranty, express or implied, is made.
Prepared by Corona Integrated Technologies Inc.