MATERIAL SAFETY DATA SHEET
- PRODUCT IDENTIFICATION AND USE – FOR
NON-PERSISTENT SMOKE
Product: Corona Thermal Fog Fluid 200B
- Product code: 200B
- Product use: Generators producing a thermal
aerosol (Colt 3, Spirit 900 B)
- Manufacturer: Corona Integrated Technologies
Inc., 6215 Overstone Drive,
- West Vancouver, B.C., Canada. Telephone:
1-888-878-9433
- Emergency telephone number: 1-888-878-9433
-
- **No significant immediate hazards for
emergency response are known.
INGREDIENTS
Main ingredient: Propylene glycol USP (CAS# 57-55-6)
-
- PHYSICAL DATA*
Physical State: Colorless viscous liquid
Odor: Odorless
Vapor pressure: 0.129 mmHg @ 25ºC
Vapor density: 2.62
Boiling Point: 370ºF, 188ºC
Specific gravity: 1.036 @ 25ºC
-
- FIRE AND EXPLOSION DATA*
Flash point: 99oC (closed cup); 107ºC (open cup)
Upper flammable limit: 12.5% by volume
Lower flammable limit: 2.62% by volume
Auto-ignition temperature: 371ºC
-
- REACTIVITY DATA*
Chemical stability: Stable under moderate temperature
Incompatibility with other materials: Oxidizing material
Hazardous decomposition products: Carbon monoxide, aldehydes when heated to very high temperatures
-
- TOXICOLOGICAL PROPERTIES*
Propylene glycol (PG) is a low toxicity compound widely used as a food additive, in pharmaceutical preparations, in cosmetics, and in the workplace-for example, water based paints, de-icing fluids, and cooling liquids. Propylene glycol may cause contact allergy, but there is sparse information on health effects from occupational exposure to PG. Mists may cause mild irritation of upper respiratory tract.
-
- PREVENTATIVE MEASURES
Eye/face protection: Use safety glasses.
Skin protection: No precautions other than clean body-covering clothing should be needed.
Respiratory protection: Atmospheric levels should be maintained below the exposure guideline. For most conditions, no respiratory protection should be needed.
Disposal: All disposal methods must be in compliance with all Federal, State/Provincial and local laws and regulations. Regulations may vary in different locations.
Storage: Keep containers tightly closed when not in use
Fire extinguishing media: Water fog or fine spray, carbon dioxide, dry chemical, foam. Do not use direct water stream.
-
- FIRST AID
Eyes: Flush eyes with plenty of water
Skin: Wash off in flowing water or shower
Ingestion: No adverse effects
Inhalation: Remove to fresh air if effects occur. Consult a physician.
-
NFPA Hazard Classification
Health: 0 Materials that, on exposure under fire conditions, offer no hazard beyond that of ordinary combustible material.
Flammability: 1 This degree includes materials that must be preheated before ignition will occur.
Instability: 0 This degree includes materials that are normally stable, even under fire exposure conditions, and that do not react with water. Normal fire fighting procedures may be used.
-
- U.S. REGULATIONS
TSCA: All ingredients are on the TSCA inventory, or are not required to be listed on the TSCA inventory.
OSHA: This is not a “Hazardous Chemical”.
-
- CANADIAN REGULATIONS
WHMIS: The Canadian Workplace Hazardous Materials Information System (WHMIS) classification for this product is: This product is not a “Controlled Product” under WHMIS
Corona Integrated Technologies Inc. has no control over the management practices or manufacturing processes of parties handling or using this material. The information presented here pertains only to the product as shipped in its intended condition as described herein.
Corona Integrated Technologies Inc. has no
control over the management practices or manufacturing processes of parties
handling or using this material. The information presented here pertains only to
the product as shipped in its intended condition as described herein.
Effective Date: 01/15/2006
Updated on
The information herein is given in good faith,
but no warranty, express or implied, is made.
* Broad characteristics of main ingredient - for more background details see
http://chem2.sis.nlm.nih.gov/chemidplus/ProxyServlet?objectHandle=DBMaint&actionHandle=default&nextPage=jsp/chemidlite/ResultScreen.jsp&TXTSUPERLISTID=000057556
Prepared by Corona Integrated Technologies Inc.
Verified (3/2/2006) by Concept Engineering Ltd., 7 Woodlands Business Park, Maidenhead, Berks, SL6 3UA, England.
Verified (4/10/2006) by Precision Laboratories Ltd., 8585 -123rd Street, Surrey, BC, Canada V3W 6E2