MATERIAL SAFETY DATA SHEET

PRODUCT IDENTIFICATION AND USE
Product: Corona Smoke Fluid 135 and 180
Product code: 135 or 180
Product use: Generators producing an artificial fog (Vicount series, Aviator, Artem, Aerotech, Cirrus, Sprinkler testing system)
Supplier: Corona Integrated Technologies Inc., 6215 Overstone Drive,
West Vancouver, B.C, Canada V7W 1X7. 
Telephone: 1-888-878-9433
Emergency telephone number: 1-888-878-9433

No hazards for emergency response are known.

COMPOSITION INFORMATION
Ingredients: Contains White Mineral Oil CAS # 8042-47-5 (complies with Food and Drug Administration Regulation 178.3570 code of Federal Regulations, Title 21). 

IMMEDIATE HEALTH EFFECTS
Eye: Not expected to cause prolonged or significant eye irritation.
Skin: Contact with the skin is not expected to cause prolonged or significant irritation. Contact with the skin is not expected to cause an allergic skin response. Not expected to be harmful to internal organs if absorbed through the skin.
Ingestion: Not expected to be harmful if swallowed.
Inhalation: Not expected to be harmful if inhaled. Contains a petroleum-based mineral oil. May cause respiratory irritation or other pulmonary effects following prolonged or repeated inhalation of oil mist at airborne levels above the recommended mineral oil mist exposure limit. Symptoms of respiratory irritation may include coughing and difficulty breathing.

FIRST AID
Eye: No specific first aid measures are required. As a precaution, remove contact lenses, if worn, and flush eyes with water.
Skin: No specific first aid measures are required. As a precaution, remove clothing and shoes if contaminated. To remove the material from skin, use soap and water.
Ingestion: No specific first aid measures are required. Do not induce vomiting. As a precaution, get medical advice.
Inhalation: No specific first aid measures are required. If exposed to excessive levels of material in the air, move the exposed person to fresh air. Get medical attention if coughing or respiratory discomfort occurs.

FIRE AND OTHER PROTECTION ISSUES
Classification: OSHA Classification (29 CFR 1910.1200): Not classified by OSHA as flammable or combustible.
NFPA Ratings: Health: 0 Flammability: 1 Reactivity: 0
HMIS Ratings: Health: 0 Flammability: 1 Reactivity: 0
Flashpoint: (Cleveland Open Cup) 129°C (265°F) (Min)
Auto-ignition: No Data Available 
Flammability (Explosive) Limits (% by volume in air): Lower: Not Applicable Upper: Not Applicable 
Extinguishing Media: Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames. 
Protective measures: Eliminate all sources of ignition in vicinity of spilled material. 
General Handling Information: Avoid contaminating soil or releasing this material into sewage and drainage systems and bodies of water.
Static Hazard: Electrostatic charge may accumulate and create a hazardous condition when handling this material. For more information, refer to OSHA Standard 29 CFR 1910.106, 'Flammable and Combustible Liquids', National Fire Protection Association (NFPA 77, 'Recommended Practice on Static Electricity', and/or the American Petroleum Institute (API) Recommended Practice 2003, 'Protection Against Ignitions Arising Out of Static, Lightning, and Stray Currents'. 
Container Warnings: Container is not designed to contain pressure. Do not use pressure to empty container or it may rupture with explosive force.

PERSONAL PROTECTION CONSIDERATIONS
Eye/Face Protection: No special eye protection is normally required.
Skin Protection: No special protective clothing is normally required.
Respiratory Protection: No respiratory protection is normally required. If user operations generate an oil mist, determine if airborne concentrations are below the occupational exposure limit for mineral oil mist. If not, wear an approved respirator that provides adequate protection from the measured concentrations of this material. 

PHYSICAL AND CHEMICAL PROPERTIES
(the data are typical values and do not constitute a specification)
Color: Colorless
Physical State: Liquid
Odor: Petroleum odor
pH: Not Applicable
Vapor Pressure: <0.01 mmHg @ 37.8°C (100°F)
Vapor Density (Air = 1): >1
Boiling Point: >260°C (500°F)
Solubility: Soluble in hydrocarbons; insoluble in water
Freezing Point: Not Applicable
Melting Point: Not Applicable
Specific Gravity: 0.82 - 0.86 @ 15.6°C (60.1°F) / 15.6°C (60.1°F)
Viscosity: 7.5 cSt - 90 cSt @ 40°C (104°F) (Min)
Chemical Stability: This material is considered stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.
Incompatibility With Other Materials: May react with strong acids or strong oxidizing agents, such as chlorates, nitrates, peroxides, etc.
Hazardous Decomposition Products: None known (None expected)
Hazardous Polymerization: Hazardous polymerization will not occur.

Environmental implication: This material is considered inherently biodegradable.

TRANSPORT INFORMATION
DOT Shipping Description: PETROLEUM OIL, N.O.I.B.N.; NOT REGULATED AS A HAZARDOUS MATERIAL FOR TRANSPORTATION UNDER 49 CFR 
IMO/IMDG Shipping Description: NOT REGULATED AS DANGEROUS GOODS FOR TRANSPORTATION UNDER THE IMDG CODE 
ICAO/IATA Shipping Description: NOT REGULATED AS DANGEROUS GOODS FOR TRANSPORTATION UNDER ICAO 

REGULATORY INFORMATION

EPCRA 311/312 Categories:
1. Immediate (Acute) Health Effects: NO
2. Delayed (Chronic) Health Effects: NO
3. Fire Hazard: NO
4. Sudden Release of Pressure Hazard: NO
5. Reactivity Hazard: NO

Chemical Inventories: All components comply with the following chemical inventory requirements: AICS (Australia), DSL (Canada), EINECS (European Union), KECI (Korea), PICCS (Philippines), TSCA (United States). 

New Jersey RTK Classification: Under the New Jersey Right-to-Know Act L. 1983 Chapter 315 N.J.S.A. 34:5A-1 et. seq., the product is to be identified as follows: PETROLEUM OIL 

WHMIS Classification: This product is not considered a controlled product according to the criteria of the Canadian Controlled Products Regulations. Corona Integrated Technologies Inc. has no control over the management practices or manufacturing processes of parties handling or using this material. The information presented here pertains only to the product as shipped in its intended condition as described herein.

Effective Date: 09/17/2008                                  Updated on

The information herein is given in good faith, but no warranty, express or implied, is made.
Prepared by Corona Integrated Technologies Inc.
Verified (9/17/08) by New Concept Chemical Products LLC, 3815 Bakerview Spur #4, Bellingham, WA 98226, USA
Verified (3/2/06) by Concept Engineering Ltd., 7 Woodlands Business Park, Maidenhead, Berks, SL6 3UA, England.